4-7. Maximum Output Current Test
a. Test Equipment and Materials. None.
b. Test Connections and Conditions. None.
c. Procedure. The following procedure is ap-
plicable to Power Supply PP-3514/U.
--
Personnel may find it convenient to arrange
the checklist in a manner similar to that shown
below:
1. Voltmeter regulation test . . . . . . . . . . . . . .
Voltage must not vary more
than 0.09 volt dc (no
load to full load).
2. Meter calibration test . . . . . . . . . . . . . . . .
10 ma dc 0.3.
3. Maximum output voltage test . . . . . . . . . .
30.5 to 32 volts dc.
4. Maximum output current test . . . . . . . . . .
325 to 330 ma dc.