LUBRICATION ORDER
L05-6115-434-12
18 OCTOBER 1979 (SUPERSEDES LO5-6115-434-12, 30 December 1968)
POWER UNIT UTILITY PACK: GAS TURBINE ENGINE
DRIVEN (AIRESEARCH MODEL PPU85-5 TYPE A)
Reference: TM5-6115-434-12, C9100-1L
Clean fittings before lubricating. Clean parts with
Intervals and related task-hour times are based on normal
SOLVENT dry cleaning SD-2. Dry before lubricating.
hours of operation. The task-hour time specified is the
Drain crankcase when HOT. Fill and check level. The
time you need to do all the services prescribed for a
lowest level of maintenance authorized to lubricate a point
particular interval. Change the interval If your lubricants
is indicated by one of the following: (C) Operator] crew; or
are contaminated or It you are operating the equipment
(0) Organizational Maintenance.
under adverse operating conditions, including longer-than-
usual operating hours. You may extend the Interval during
.You can Improve this publication by calling attention to
periods of low activity, but you must take adequate
errors and by recommending improvements and by stating
preservation precautions.
your reasons for the recommendations. Your letter or DA
Form 2028 (Recommended Changes to Publications and
Forms) should be mailed direct to Commander, U.S. Army
Troop Support and Aviation Material Readiness Command,
ATTN: DRSTS-MTPS, 4300 Goodfellow Blvd., St. Louis
*The time specified is the time required to perform all
MO 63120. A reply will be furnished direct to you.
services at the particular Interval.
LUBRICANT INTERVAL
LUBRICANT INTERVAL
Oil Fill Cap and
Oil Filter
Dipstick
(Disassemble, clean housing,
(Check oil level and
renew element, and
replenish as required.)
Oil Drain Cap
(Drain and refill.) (0)
*TOTAL TASK HR.
*TOTAL TASK-HR.
INTERVAL
TASK-HR
INTERVAL
MAN-HR
10
0.1
500
0.6
STS Form 2273
CARD 1 OF 2
1 Dec 76