L05-6115-586-12
LUBRICATION ORDER
18 OCTOBER 1979 (Supersedes L05-6115-586-12, 18 November 1972)
POWER PLANT UTILITY, GAS TURBINE ENGINE DRIVEN
(LIBBY WELDING CO. MODEL LPU-71)
Reference: TM5-6115-586-12, C9100-IL
Intervals and related task-hour times are based on
Clean parts with SOLVENT dry cleaning, SD-2. Dry
normal hours of operation. The task-hour time specified
before lubricating. Drain crankcase when HOT. Fill and
is the time you need to do all the services prescribed for
check level. The lowest level of maintenance authorized
a particular interval.
Change the interval if your
to lubricate a point Is Indicated by one of the following:
lubricants are contaminated or if you are operating the
(C) Operator/crew; or (O) Organizational Maintenance.
equipment under adverse operating conditions, including
longer-than-usual operating hours. You may extend the
You can Improve this publication by calling attention to
interval during periods of low activity, but you must take
errors and by recommending improvements and by
adequate preservation precautions.
stating your reasons for the recommendations. Your
letter or DA Form 2028 (Recommended Changes to
Publications and Forms) should be mailed direct to
'The time specified is the time required to
Commander, U.S. Army Troop Support and Aviation
perform all services at the particular
interval.
Material Readiness Command, ATTN: DRSTS-MTPS,
4300 Goodfellow Blvd., St. Louls MO 63120. A reply will
be furnished direct to you.
FOLD
FOLDI
LUBRICANT INTERVAL
INTERVAL LUBRICANT
Oil Fill Cap and Dip-
stick
(Check oil level and
replenish as required)
(See note 2) (0)
Oil Drain Cap
(Drain and refill.)(O)
Oil Filter
(Disassemble, clean
housing, renew element,
and reassemble.)
(See note 1.) (0)
*TOTAL TASK-HR
'TOTAL TASK-HR
INTERVAL
TASK-HR
INTERVAL
TASK-HR
10
0.1
500
0.6
CARD 1 OF 2