TM 11-5820-765-34
TEST LEGEND
TEST EQUIPMENT
E Q U I P M E N T UNDER TEST
T E S T PROCEDURE
PERFORMANCE
STANDARD
NOTE
Keep test equipment at these settings except where noted.
Power ON.
1. Equipment set as noted above.
DC voltage adjust R4; 28-volt output.
Transient voltage less than 5 volts.
2. Close test switch.
Check dynamic response on
Response
times:
PP-4763: Recovery to within 1.85 volts of final
value less than 50 milliseconds.
PP-4763A: Recovery to within 37 percent of final
value less than 75 milliseconds.
Transient voltage less than 5 volts.
3. Open test switch.
Check dynamic response on
Response
times:
PP-4763: Recovery to within 1.85 volts of final
value less than 100 milliseconds.
PP-4763A: Recovery to within 37 percent of final
voltage
less
than
125
milliseconds.
DC voltage overshoot less than 5 volts.
4. Power OFF.
Check dynamic response on
5. Power ON.
DC voltage overshoot less than 5 volts.
Check dynamic response on
Power OFF. Turn off power to all test equipment.