Table 11-1. Engine Operating Limits (continued)
Condition
Limit Requirements
Observation
Leakage:
From accessory drain only.
Fuel
1 drop per minute max
Fuel leakage from combustor
and plenum drain valves is
permitted only after a false
start or blowout.
From output shaft seal
Oil
5 cc per hour max
Duty Cycle:
Starter Motor
Battery Starts -
Six consecutive normal
Using AGPU battery or an
starts at ten minute
external power source which
intervals, after which
limits current output to
one hour off time
800 amps maximum (soft-
shall be required for
start).
additional starts.
Battery Cranking -
Three consecutive 30
Using AGPU battery or an
second cranking cycles
external power source which
and then 20 minutes
limits current output to
off time.
800 amps maximum (soft-
cranking).
11-4