TM 5-1730-245-14
SECTION IV. OPERATION UNDER UNUSUAL CONDITIONS
2.12 LOW TEMPERATURE OPERATION .
a. Position valves and hose connections as for operation under usual conditions. Refer to Section III.
b. Engine oil. Notify Unit Maintenance
c. Starting. Hold the starter switch (9, figure 2-1) in the HEAT position as in normal starting, and move it
counterclockwise to the HEAT/START position until the engine fires. As soon as the engine fires return the
starter switch to the HEAT position and hold it there for 20-30 seconds.
d. Allow the engine to warm up for five minutes before increasing speed or applying full system pressure
2.13 HIGH TEMPERATURE OPERATION.
a. Engine oil. Notify Unit Maintenance.
b. Use the START position of the starter switch (9, figure 2-1) without the use of HEAT.
2.14 NUCLEAR, BIOLOGICAL, AND CHEMICAL (NBC) DECONTAMINATION PROCEDURES.
NOTE
DETAILED DECONTAMINATION PROCEDURES ARE CONDUCTED IN
ACCORDANCE WITH FM 3-3, FM 34 AND FM 3-5.
2.14.1 General.
Emergency NBC decontamination procedures are conducted In accordance with the local Standard Operating
Procedures (SOP).
2-14