Combustion Section Components Inspection/Check Procedures
Table 9-3.
Item
Requirements
NO.
Nomenclature
Inspect/Check
Visually check gasket
1
Filler Cap
allowed.
material.
Check attached cable for
Cable shall be secure.
security.
No galled, peened, crossed
Visually check for galled,
or stripped threads allowed.
peened, crossed and stripped
threads.
No cracks, distortion or
Visually check clamp for
Clamp
5
damaged threads allowed.
cracks, distortion and
damaged threads.
Visually check fuel nozzle
Replace fuel nozzle assem-
Fuel Nozzle
7
Assembly
assembly for burring, flat-
bly, if damage is indicated.
tening, scratching of conical
surface, or crossed or worn
threads.
No damage allowed. Refer
Visually check insulation
Combustion
9
to paragraph e. for repair.
material for damage (bare
Chamber Cap
metal visible).
No cracks, dents, deforma-
Visually check for cracks,
tion or damaged threads
dents, deformation and
allowed.
damaged threads.
No cracks or damage allowed.
Perform flourescent penetrant
inspection on inside surface or
to outside surface if insula-
ting material has been removed.
Visually and dimensionally
Refer to paragraph c.
Combustion
10
Chamber