TM 55-4920-431-13
Analog Converter Replacement.
a.
b.
Disconnect electrical connector (P4) from control assembly (19, figure 5-1).
c.
Remove top four screws (20), washers (21), and control assembly (19).
d.
Install replacement control assembly (19) and secure with four screws (20)
and washers (21).
e.
Connect electrical connector (P4) to control assembly (19).
f.
Reinstall panel and case lid.
g.
Relay Replacement.
a.
b.
Lift relay hold down spring (5, figure 5-3) from socket (4).
c.
Pull relay (1) out of socket (4).
d.
Install replacement relay (1) into socket (4). Reinstall relay hold down
spring (5) over relay.
e.
Reinstall panel and case lid.
Fuse Replacement.
a.
b.
c.
Install replacement fuse.
d.
Reinstall panel and case lid.
Meter Replacement.
a.
b.
Refer to wiring diagram, figure FO-2 and identify wire leads to be disconnec-
ted from meter. Wires 45, 46, and 47 connect to TEMP meter (M2). Wires
48, 49, and 50 connect to SPEED meter (M1).
c.
Loosen and remove nuts from meter posts.
Remove wire leads from posts.
d.
Remove three retaining screws and nuts mounting the SPEED meter (M1) (1,
4-16