INTRODUCTION
tory Equipment. Use equipment forms and rec-
o r d s in accordance with instructions in TM
This manual provides instruction for instal-
38-750.
l a t i o n , operation, and maintenance of Power
b. Report of Damaged or Improper Ship-
S u p p l y PP2309A/U. The maintenance alloca-
ment. Fill out and forward DD Form 6 (Report
tion chart, basic issue items list, and the repair
o f Damaged or Improper Shipment) as pre-
p a r t s and special tool lists are contained in
s c r i b e d in AR 70058 (Army), NAVSANDA
appendices II, III, and IV.
P u b l i c a t i o n 378 (Navy), and AFR 71-4 (Air
Force).
c. Reporting of Equipment Manual lmprove-
m e n t s . The direct reporting of errors, omis-
sions, and recommendations for improving this
1-2. Index of
Publications
e q u i p m e n t manual by the individual user, is
authorized and encouraged. DA Form 2028 will
Refer to the latest issue of DA Pam 310-4
t o detemine whether there are new editions,
be used for reporting these improvements. This
c h a n g e s , or additional publications pertaining
f o r m may be completed using pencil, pen, or
to the euipment. Department of the Army
typewriter. DA Form 2028 will be completed by
Pamphlet No. 310-4 is an index of current
the individual using the manual and forwarded
t e c h n i c a l manuals, technical bulletins, supply
d i r e c t to Commanding General, U. S. Army
manuals (types 7, 8, and 9), supply bulletins,
E l e c t r o n i c s Command, ATTN: AMSEL-MR
l u b r i c a t i o n orders, and modification work or-
(NMP)-MA,
Fort
Monmouth,
New
Jersey
d e r s that are available through publications
07703.
supply channels. The index lists the individual
parts (-10, -20, -35P, etc) and the latest
Purpose
c h a n g e s to and revisions of each equipment
P o w e r Supply PP-2309A/U is designed to
publication.
c o n v e r t nominal 115 volts, single phase, 60
c y c l e s per second, to regulated 0 to 36 volts
direct current (dc).
a . Reports of Maintenance and Unsatisfac-
1-5. Technical and Physical Characteristics
Ac input _ _ _ _ _ 95 to 130 volts, single phase, 60 cycles per second.
Dc output voltage_ _0 to 36 volts dc.
Dc output current _ _ _ 15 amperes maximum.
Regulation_ _ _ _ _0.5 percent in 5- to 36-volt range. 40 millivolts in 2- to 5-volt range.
1 percent rms maximum at 36 volts and 2 percent rms maximum at 2
Ripple
Volts with full load.
Dimensions
19 inches wide, 12 inches deep, 12 1/4 inches high.
Mounting
On standard I9 inch relay rack.
Metering
Finish
G r a y hammertone.