TM 55-1730-229-12
AC 320A0-OMM-000
TO 35C2-3-473-1
TM 1730-12/1
7.
CAP
1.
CLAMP, HOSE
13.
8.
2.
HOSE
SETSCREW
DEICER OUTLET CAP
14.
SCREW
15.
BRACKET
9.
3.
VALVE WIRING BODY
4.
WIRING
WASHER
16.
10.
5.
CASE
11.
SCREW
COVER, ACCESS
17.
6.
WASHER
WASHER
12.
(6) Loosen setscrew (8) installed
(3) Install solenoid case (11),
in bracket (9).
winding (10), and cap (7) over valve
fitting and secure with screw (5) and
(7) Remove valve body (3).
washer (6).
Ensure that wiring out of
c. Install.
(1) Install valve body (3) through
(4) Reconnect wiring (4).
bottom of hole on bracket, and install
washer (12). Ensure that arrow on valve
body is pointing toward front of AGPU.
(5) Install hoses (2) on valve
body (3) fittings and secure with clamps
(2) Install setscrew (8) through
(1).
threaded hole in bracket (9) to hold
valve.
(6) Install two access covers.