TM 11-6130-243-35
F U N C T I O N I N G OF EQUIPMENT
plied to the input circuit consisting of circuit breaker
a. This manual contains direct support, general sup-
switch CB1, the tap board, VOLTAGE ADJUST switch
port, and depot maintenance instructions for Power
S2, indicator lamp DS1, and power transformer T1. The
Supply PP-4606/G (power supply). It includes instruc-
tap board connects the input powerlines to the primary
tions appropriate for troubleshooting, testing, and
repairing the equipment. It also lists tools, materials,
nected between various terminals on the tap board to
and test equipment required for maintenance, Func-
permit operation of the power supply from either 220-
tional analysis of the equipment is covered in this
or 440-volt alternating current (at) power mains. With
chapter.
circuit breaker switch CB1 set to POWER ON, input
b. The complete technical manual for this equip-
power is applied through the jumpers on the tap board
ment includes TM11-6130-243-12.
and VOLTAGE ADJUST switch S2 to the primary
c. You can help improve this manual. If you find
windings of stepdown power transformer T1 and in-
any mistakes or if you know of a way to improve the
dicator light DS1. The input circuit to transformer Tl is
procedures, please let us know. Mail your letter or DA
wye-connected, the output circuit from the transformer
Form 2028 (Recommended Changes to Publications and
is delta-connected. VOLTAGE ADJUST switch S2 con-
Blank Forms) direct to Commander, US Army
trols application of input power to specific taps of the
primary windings of transformer T1. The ac output
DRSEL-ME-MQ, Fort Monmouth, NJ 07703. In either
voltages from the secondary windings of the
case, a reply will be furnished direct to you.
NOTE
(dc) voltage by full-wave rectifiers CR1 through CR6
For applicable forms and records, see
and filtered by the network consisting of capacitors C1
through C8 and inductor L1. Resistors R1 and R2 com-
prise a load network across the rectifiers. The power
1-2. Index of
Technical Publications
supply current and voltage are monitored by DIRECT
Refer to the latest issue of DA Pam 310-4 to determine
CURRENT AMPERES meter M1 and DIRECT CUR-
whether there are new editions, changes, modification
RENT VOLTS meter M2. Resistor R3 is the ammeter
work orders (MWO'S) or additional publications per-
shunt resistor. Resistor R4 is the meter movement series
taining to the equipment.
resistor used to establish the deflection sensitivity of the
ammeter. AMMETER switch S1 (spring-loaded to the
OFF position) connects the ammeter to the output cir-
cuit when depressed to the READ position.
Three-phase, wye-connected primary input power is ap-
Change1