TM 11-6130-266-15
Figure 5-3. Post regular control assembly 12, parts location.
Measured between
Dc resistance
may differ slightly from the values given in the
Part
terminals
(ohms)
A2L3
1-2
Less than 1.
A2L4
1-2
Less than 1.
A2L5
1-2
Less than 1.
b.
A2L6
1-2
Less than 1.
A4A1L1
10-11
400
Measured between
DC resistance
12-13
150
Part
terminals
(ohms)
12-13
150
L1
1-2
Less than 1.
14-15
2
3-9
9
16-17
10
T1
9-11
Less than 10.
18-19
10
12-14
Less than 1.
A4A1T1
1-2
56
A1K1
1-16
650
3-5
5.8
A1K2
1-16
650
6-7
1.26
A2L1
1-2
Less than 1.
8-9
1.26
A2L2
1-2
Less than 1.
A6K1
3-6
428(PP-6224/U)
X1-X2
*260(PP-6224A/U)
* Measure with DS2 NORM indicator lamp pulled out
5-6 Change 3