TM
55-1730-229-12
AG
320A0-OMM-000
TO
35C2-3-473-1
TM
1730-12/1
Table 4-1.
Organizational Preventive Maintenance Checks and Services (continued)
Organizational
Work Time
M/H
Inspection Procedures
M
S
H
W
CONTROL PANEL AND ELECTRICAL COMPARTMENT
(continued)
(b) Inspect starter and external dc con-
tactors for damage or loose connec-
tions.
for signs of corrosion. Check that
cable connections are secure.
(ECU) for signs of corrosion. Check
that cable connections are secure.
(3) Inspect portion of main wiring harness
extending into electrical compartment for
frayed or damaged wires, loose wire con-
nections, and burned wires.
BATTERY CHARGER
2
0.1
Remove screws securing cover below control panel
and remove cover. Inspect battery charger for
signs of corrosion. Check that cable connections
are secure.
BATTERY
1
0.3
AIR CLEANER
0.2
3
Remove louvered cover and inspect air cleaner for
missing tubes, or damage. Remove debris and
vacuum out all tubes and face of cleaner. Re-
place louvered cover.
GENERATOR
4
0.1
4-12