TM 55-1730-229-12
AG 320A0-OMM-000
TO 35C2-3-473-1
TM 1730-12/1
Table 4-2.
Organizational Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(continued)
79.
f.
Set switch or breaker to each position listed in column (C).
and check continuity between terminals listed in column (D)
for normal indication of column (E).
If any continuity check is not normal, replace switch or
g.
If all continuity checks are normal, switch or circuit
h.
breaker is good. Reconnect any wires or connectors that were
disconnected for test.
HYDRAULIC CONTROL PANEL SWITCH AND CIRCUIT BREAKER MALFUNCTIONS.
80.
If any hydraulic control panel switch or circuit breaker is suspected of
malfunction, test the switch or circuit breakers as follows:
a. Shut down engine.
b.
column (A). Remove hydraulic electrical panel (paragraph
Disconnect wires as indicated in column (B).
d.
Set switch or breaker to each position listed in Column (C),
e.
and check continuity between terminals listed in column (D)
for normal indications of column (E).
f.
If any continuity check is not normal, replace switch or
check.
If all continuity checks are normal, switch or circuit
g.
breaker is good. Reconnect any wires that were disconnected
for test.