TM 55-1730-229-12
AG 320A0-OMM-000
TO 35C2-3-473-1
TM 1730-12/1
Control Panel Switch and Circuit Breaker Continuity Checks
(F)
(E)
(D)
(B)
(C)
(A)
Fig.
Normal
Switch
Ref.
Indication
Disconnect
Position
Switch
From
To
(see note 3)
Open
1S1-6
STOP
1S1-1
ENGINE
P5 from control
1S1-12
Open
1S1-7
CONTROL
panel 1J5
Open
1S1-11
1S1-7
(1S1).
1S1-6
RUN
Open
1S1-1
Continuity
1S1-11
1S1-7
Continuity
1S1-6
START
1S1-1
Continuity
1S1-12
1S1-7
FO-1
Open
1S2-3
OFF
1S2-2
MASTER
Wires from
FO-1
1S2-6
SWITCH
switch termi-
1S2-5
Open
Open
1S2-9
1S2-8
nals 1S2-2, -5,
(1S2)
FO-1
1S2-12
Open
-8 , and -11
1S2-11
FO-1
Continuity
1S2-3
ON
1S2-2
FO-1
Continuity
1s2-6
1S2-5
Continuity
1S2-9
1s2-8
FO-1
Continuity
1S2-12
1S2-11
Open
OFF
1S3-2
Wires from
1S3-3
DRIVE
Open
lS3-6
switch terminals
lS3-5
(1S3)
1S3-2 and 1S3-5
Continuity
ON
1S3-2
1S3-3
Continuity
1S3-6
1S3-5
1S4-NO1
Open
1S4-C1
PRESS TO
P6 from control
Released
(wire
TEST
panel 1J6
(wire
L27A20).
L30A20N).
(1S4)
1S4-NO2
1S4-C2
Open
(wire
(wire
L28A20).
L1C20).
1S4-NO1
Continuity
1S4-C1
Pressed
1S4-NO2
Continuity
1S4-C2