Table 4-2.
Organizational Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(continued)
95.
c. Perform tests indicated in table 4-9 for contactor in
deactivated state.
NOTE
Two test leads made from 20 gage wire are required to step d.
Each lead should be terminated on one end with a female con-
nector pin, and with a clip on other end.
d.
Connect one test lead between pin A on the contactor elec-
trical connector J1 and the positive terminal screw on back
of slave receptacle. Connect other lead between pin B on con-
tactor connector and negative terminal on slave receptacle.
e.
Connect battery.
f.
Perform tests indicated in table 4-9 for contactor in
activated state.
Disconnect battery.
g.
h.
Disconnect test leads.
i.
If all indications in table 4-9 were normal, reconnect wires
and connector to contactor, and install terminal shields. If
any condition was not normal, install new relay.
IGNITION UNIT MALFUNCTION.
96.
If the ignition unit is suspected of malfunction, test the unit as follows
a.
Disconnect battery. Disconnect electrical connector from
pin B (positive) of electrical connector.
Do not exceed starter duty cycle.