TM 55-1730-229-12
TO 35C2-3-473-1
/5
12-4-36
1.
AC OUTPUT UC CURRENT TRANSFORMER (T3)
3.
AC OUTPUT 0B CURRENT TRANSFORMER (T4)
2.
5.
AC GENERATOR (83-360D ONLY)
a. DC Power Generation and Con-
control system components are grouped in
trol. This system is shown schemati-
two functional systems: dc power gener-
ation and control, and ac power genera-
includes the dc sections of the ac/dc
tion and control.
(GCU), dc output contactor K2, shunt
R1, 95% enable relay 3K1, dc-to-ac in-
NOTE
verter, and associated control panel
(Maintenance
switches and instruments.
The control panel controls and in-
of shunt R1 and relay 3K1, AC to DC trans-
struments associated with these
former rectifier unit (83-360D only) is
provided in section IX.)
systems are described in this sec-
tion. Maintenance of the control
(1) The generator includes two
panel components is covered in
permanent magnet (PM) stator wind-
section XVII.
ings, an exciter field, and two stator