TM 55-1730-229-12
AG 320A0-OMM-000
TO 35C2-3-473-1
TM 1730-12/1
Indicators.
Install
(1) Insert lamp socket (8) through
hole in panel (16).
(2) Install washer (10) and nut
(11).
(3) Connect wires to lamp socket
(8).
(4) Install lamp (7) and lens (6)
(if not already installed in lamp soc-
ket).
(5) Perform steps (6) through (8)
(6) Reconnect battery cable.
c. Remove
Hourmeter.
(See
(1) Perform steps (1) through (5)
1.
SWITCH
10. WASHER
2.
NUT
11. NUT
(2) Tag and remove wires from
3.
WASHER
12. CIRCUIT BREAKER
hourmeter (14).
WASHER,
4.
13. SCREW
POSITIONING
14. HOURMETER
(3) Remove two screws (13) and
5.
NUT,
15. NUT
remove hourmeter (14) from panel (16).
ADJUSTMENT
16. PANEL
LENS
6.
17. SWITCH GUARD
7.
LAMP
18. SOCKET, LAMP
d.
Install Hourmeter.
8.
SOCKET, LAMP
19. LAMP, UTILITY
9.
SCREWS
20. SCREW
(1) Insert hourmeter (14) through
hole in panel (16).
Electrical Panel
(2) Secure hourmeter to panel with
two screws (13).
(3) Tag and remove wires from lamp
socket (8).
(3) Connect wires to hourmeter
(14).
(4) Remove retaining nut (11) and
washer (10) and remove lamp socket (8)
(4) Perform steps (6) through (9)
from panel (16).