TM 55-1730-229-12
1.
11.
TURBINE PLENUM
GEARCASE ASSEMBLY
2.
12.
HYDRAULIC PUMP PAD
TORUS SCROLL
3.
13.
HYDRAULIC PUMP SPLINED DRIVE
TURBINE ROTOR
4.
VENT
14.
DESWIRL ASSEMBLY
5.
15.
COMPRESSOR ROTOR
6.
16.
DEFLECTOR
7.
17.
SIDE MOUNTING PAD (2)
CONTAINMENT RING
8.
18.
INLET DUCT FITTING
9.
19.
PLANETARY GEAR SET
10.
20.
COMBUSTOR CHAMBER
LOAD CONTROL VALVE (LCV)
(2) Inspect threaded fittings on both ends of
away from open flames or other sources of
check valve for damage. No damage is allowed.
ignition.
Inspect interior of check valve. If interior appears
c. Service.
dirty or contaminated, clean by dipping in degreasing
solvent, MIL-PRF-680.
Degreasing Solvent, MIL-PRF-680, is com-
bustible and toxic to eyes, skin, and respiratory
(1) Install check valves (3) with new packing (4).
tract. Wear protective gloves and goggles/face
Ensure that arrow on valve body points into drain tube.
shield.
Avoid repeated or prolonged con-
tact. Use only in well ventilated ares (or use
(2) Connect drain lines (2) to check valves (3)
approved respirator as determined by local
and secure with clamps (1).
safety/industrial hygiene personnel).
Keep