Table 2-2.
Direct/General Support Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
SYSTEM READY LIGHT STAYS OFF, FLUID TEMPERATURE OVER 70F (continued)
20.
Install new temperature sensor TS1 with new packing.
d.
Reassemble module according to the procedure of paragraph
f.
8-18 starting with step a.
SYSTEM READY LIGHT ON, FLUID TEMPERATURE BELOW 70F.
21.
Shut down complete unit and replace temperature sensor TS1:
Disassemble module to gain access to the temperature sensor
a.
b.
its associated packing.
Ensure that TS1 hole in manifold is clean.
c.
Install new temperature sensor TS1 with new packing.
d.
e.
f.
Reassemble module according to the procedures of paragraph
8-18 starting with step a.
22.
160F LIGHT STAYS OFF, FLUID TEMPERATURE OVER 160F.
Step 1.
Ensure that 160F lamp is good as shown by lamp test.
Shut down complete unit and replace temperature sensor TS2:
Step 2.
a. Disassemble module to gain access to the temperature sensor
b.
its associated packing.
c. Ensure that TS2 hole in manifold is clean.
2-12