Table 2-2.
Direct/General Support Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10.
MAXIMUM PRESSURE AT HYDRAULIC MODULE OUTPUT AT ALL TIMES.
Shut down complete unit and check PRESSURE RELIEF valve for contamination,
blockage or valve malfunction:
a.
manifold hole where the PRESSURE RELIEF valve fits.
Inspect valve cartridge for signs of blockage (i.e., lodged
b.
bits of packing). Replace valve cartridge if necessary.
Replace valve packing.
c.
d.
verify operation.
OUTPUT PRESSURE GAUGE ALWAYS INDICATES ZERO.
11.
Shut down complete unit and check GAUGE SHUTOFF valve:
a.
hole where GAUGE SHUTOFF valve fits.
Inspect valve cartridge for signs of blockage (i.e., lodged
b.
bits of packing). Replace valve cartridge if necessary.
c.
Replace valve packing.
d.
operation.
HYDRAULIC SYSTEM PRESSURE CANNOT BE RELEASED AT END OF HYDRAULIC SERVICING
12.
OPERATION.
Check HIGH PRESSURE BYPASS valve for blockage:
hole where HIGH PRESSURE BYPASS valve fits.
Inspect valve cartridge for signs of blockage (i.e., lodged
b.
bits of packing). Replace valve cartridge if necessary.
2-8