Table 2-2.
Direct/General Support Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
HYDRAULIC SYSTEM PRESSURE CANNOT BE RELEASED AT END OF HYDRAULIC SERVICING
12.
OPERATION (continued)
c. Replace valve packing.
d.
verify operation.
AIRCRAFT INDICATOR SHOWS THAT NO BACK PRESSURE IS APPLIED WHEN RETURN BYPASS
13.
SELECTOR SET TO OFF.
Step 1.
Shut down complete unit and check RETURN BYPASS selector:
manifold hole where RETURN BYPASS selector fits.
Inspect selector cartridge for nicks, scratches or broken
b.
packing. Replace selector cartridge if necessary.
c. Replace selector packing.
d.
verify operation.
Step 2.
Disassemble module according to the procedure of paragraph
a.
b.
Clean manifold hole.
c.
Install new RETURN BYPASS relief valve (with new packing) in
d.
manifold.
e.
f.
step k.
2-9