Table 2-2.
Direct/General Support Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PUMP EMITS HIGH PITCH WHINE WITH LOSS OF PRESSURE AT HIGH PRESSURES (continued)
3.
Step 2.
Check HIGH PRESSURE BLEED valve:
a.
manifold where HIGH PRESSURE BLEED valve fits.
Inspect valve cartridge for nicks, scratches or broken
b.
packing. Replace valve if necessary.
Replace valve packing.
c.
d.
Verify operation.
4.
PRESSURE GAUGE INDICATION DOES NOT DROP wHILE BLEEDING AIR.
Step 1.
Shut down complete unit and check RETURN BLEED valve for clogged
condition:
manifold where RETURN BLEED valve fits.
Inspect valve cartridge for signs of blockage (i.e., lodged
b.
bits of packing). Replace valve cartridge if necessary.
c. Replace valve packing.
d.
operation.
Step 2.
Check HIGH PRESSURE BLEED valve for clogged condition:
a.
manifold where HIGH PRESSURE BLEED valve fits.
Inspect valve cartridge for signs of blockage (i.e., lodged
b.
bits of packing). Replace valve cartridge if necessary.
Replace valve packing.
c*
d.
verify operation.
2-5