TM 5-1730-245-14
6.3 THERMAL CONTROL MODULE - REPLACE.
THIS TASK CONSISTS OF:
a. Removal
b. Installation
INITIAL SETUP
Tools:
Equipment Condition:
Toolkit, General Mechanics (item 5, Section III, Appendix B).
Shop Equipment, Automotive Maintenance and Repair:
Organizational Maintenance, Common No 1, less
Material/Parts Required:
1) Disconnect tube (1) from adapter (2)
2) Remove screws (8), lockwashers (7) and connection block (3) from the hydraulic control manifold (6)
3) Remove thermal control module (4)
NOTE
Silicone sealant is used to form a new gasket Ensure surfaces are free of
1) Insert the thermal control module (4) in the cavity of the hydraulic control manifold (6).
2) Apply silicone sealant to surface of connection block (3)
3) Install the connection block (3) with screws (8) and lockwashers (7). Torque the bolts to 5 0 ft. lb./ 7
Nm.
4) Install tube (1) to adapter (2)
Figure 6-2. Thermal Control Module.
6-3