TM 55-1730-229-12
AG 320A0-OMM-000
TO 35C2-3-473-1
TM 1730-12/1
Organizational Troubleshooting (continued)
Table 4-2.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10.
(continued)
Check MASTER SWITCH 1S2 (see malfunction 79).
Step 5.
a.
operational check.
If switch is good, do step 6.
b.
Step 6.
Check battery/charger transfer relay 3K3 (see malfunction 85, step 1).
a. If relay is good, do step 7 below.
If relay test is not good , check wiring as directed i n
b.
malfunction 85, step 1.k.
Step 7.
following points (see FO-1 and FO-9):
If no continuity,
Check continuity
replace wire no.
To
From
C1018
P7-4L
P9-M
C1E18
1S2-11
J7-4R
C1F18
1S2-12
J7-5L
C1C20
P14-J
P7-5R
C2A20N
GND TB
P14-I
If no continuity, replace indicated wire, and perform
a.
operational check.
b.
On hydraulic module, check wires between 4TB1-2 and 4S3, and between
Step 8.
4TB1-12 and the indicator light negative terminals (see FO-9) for
continuity.
4-37