TM
55-1730-229-12
AG
320A0-OMM-000
TO
35C2-3-473-1
TM
1730-12/1
Organizational Troubleshooting (continued)
Table 4-2.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
62.
(continued)
a.
If resistance is between 20 and 30 ohms, reconnect wire and
do step 13.
b.
If resistance is not between 20 and 30 ohms, replace resistor
Test PNEUMATIC POWER switch 1S8 (malfunction 79).
Step 13.
a.
operational check.
b.
If switch tests good, do step 14.
Step 14.
Remove battery charger access cover. Disconnect main harness
connector P6 from control panel connector J6. Check for continuity
between the following points (see FO-7):
Check continuity
If no continuity,
replace wire no.
From
To
S8-2
S8-11
H1D20
H1A20
S8-12
J6-A
P6-A
TB1-13 ANODE
H1C20
H2B20
P6-B
TB1-13 CATHODE
J6-B
H2A20
1M7(+)
H3A20
J6-C
1M7(-)
P6-C
Pressure trans-
H3B20
ducer MT2(+)
GND TB
Pressure trans-
H10A20N
ducer MT2(-)
pressure transducer MT2 location.
a.
If no continuity, replace indicated wire or notify mainte-
nance supervisor.
b.
If all continuity checks good, replace PSIG PNEUMATIC meter
4-96