TM 55-1730-229-12
AG 320A0-OMM-000
TO 35C2-3-473-1
TM 1730-12/1
Table 4-2.
Organizational Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(continued)
59.
Step 3.
Remove battery charger access cover, and lower control panel (para-
4-38) from GCU. Check for continuity
between P7-9R and P12-B (see
Step 4.
Test ac contactor K1 (malfunction 95).
PNEUMATIC POWER ON INDICATOR NOT LIT (MASTER SWITCH AND PNEUMATIC POWER SWITCH
60.
ON).
Test PNEUMATIC POWER switch 1S8 (malfunction 79).
a.
b.
Remove battery charger access cover. Disconnect main harness
connector P6 from control panel connector J6. Check for
continuity between the following points (see FO-7). If no
continuity, replace indicated wire and perform operational
check.
Check continuity
If no continuity,
replace wire no.
To
From
J6-D
H4B20N
1DS13(-)
H4A20N
P6-D
GND TB
1S8-3
1DS13(+)
H7A20