d.
Install. Install exhaust ejector (see paragraph
Rework top of ejector as shown by threading
e.
MS20995N32 (Lockwire) through existing holes in perfo-
rated metal. Lace 3 to 4 passes across flue and tie off (Refer
AIR INTAKE DUCT ASSEMBLY.
3-6.
a.
(1)
roof.
Refer
to
TM
Remove
55-1730-229-12, paragraph 4-16.
(2)
Remove air cleaner assembly. Refer to TM
Tag and disconnect wires from bypass door
(3)
switch (1).
(4)
Remove two screws (2), washers (3),
spacers (4), lockwashers (5) and nuts (6) from each end of
inner duct (9) support.
Remove twenty screws (7), and washers (8)
(5)
securing inner duct (9) to rivnuts (17) on outer duct (16).
Remove inner duct. (9).
(6)
Inspect gaskets (10, 11) Replace if split or
(7)
torn.
(8)
Remove three screws (12), washers (13),
lockwashers (14), and nuts (15) seeming top of outer duct
(16) to frame.
(9)
Remove outs duct (16)
(10)
Inspect gasket (18). Replace if split or torn
b.
Repair.
(1)
Repair dent in duct sections by straight
ening.
(2)
Repair splits a cracks by welding. Regal-
vanize after welding.
Change 4