Table 4-2.
Organizational Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
16.
(continued)
b.
If relay tests good, do step 3.
Test EMERG STOP switch (see malfunction 93).
Step 3.
a.
operational check.
b.
If switch tests good, do step 4.
Step 4.
Check wires E2E18 (1S1-11 to 1S1-12) and E2B18 (1S1-11 to J5-1R)
Replace or repair open wire.
a.
b.
If wiring is good, replace starter latching relay 3K2
c. Perform operational check after replacing wire or relay.
STARTER CURRENT METER EXCEED 800 AMPS.
17.
a. Replace cable if shorted.
b.
NOTE
If STARTER CURRENT meter still reads greater than 800 amps
during engine start , engine may be overloading starter. Notify
supervisor.
GTE % RPM METER INDICATION DEFECTIVE.
18.
Step 1.
Test GTE speed sensor (see malfunction 88).
a.
perform operational check.