TM 55-1730-229-34
AG 320A0-MME-000
TO 35C2-3-473-2
TM 1730-34/1
(e) Disconnect ground lug wire
(29) by removing nut (28) and lockwasher
(27).
(f) Remove two screws (24) and
washers (25) and remove cover (30) from
AC terminal block (18).
(g) Tag and remove six AC cables
(23) by removing six nuts (20), lock-
washers (21), and washers (22). Leave
jumper (19) on terminal block.
(10) Tag and disconnect starter
cable (9).
(11) Remove engine/generator/by-
draulic pump.
to engine lifting cable (3) and lifting
NOTE
Record lockwiring method for later
installation.
2-11) and remove two capscrews (2) and
(c) Cut lockwires (12) and re-
move four capscrews (13) and washers
Remove
(14) from right engine mount.
mounting block (15), but leave Pin (17)
in place.
(d) Cut lockwires (5, 8) and re-
move eight capscrews (6, 9) and washers
(7, 10) from left engine mount. Remove
mounting block (11), but leave pin (16)
in place.
Figure 2-8. Hydraulic Pump and
(e) Check that all lines, hoses,
Engine Access
and cables have been disconnected from
engine/generator/hydraulic pump, and
(d) Tag and disconnect DC cable
that they are not in the way of engine
Tie back lines, hoses, and
removal.
(16) by removing nut (13), lockwasher
cables if required.
(14), and washer (15).
2-43