TM 55-1730-229-12
TO 35C2-3-473-1
c. Engine Start Procedure.
NOTE
(1) Perform prestart procedures in
Refer to PMCS table 3-2 for indi-
paragraph a, and observe precautions in
cators and meters that must be
paragraph b.
monitored during (D) operation.
12-2-8
(2) MASTER SWITCH (1) to ON.
(a)STARTER ON light (4) illuminated green.
(b) STARTER CURRENT meter (5) indicates
(3) Push PRESS TO TEST pushbutton (2) and
500 amp to 800 amp during cranking.
check that all indicator lights on control panel illuminate.
NOTE
(c) LOW FUEL PRESS light (6) goes out
within 10 seconds after initiating start sequence.
On the 83-360D, the DC voltage monitoring
function of the GCU has been disabled.
(d)LOW OIL PRESS light (7) goes out within
The DC VOLTAGE FAULT will not illuminate
10 seconds after engine reaches 95% speed.
when the PRESS TO TEST button is pushed.
(4)Momentarily set ENGINE CONTROL switch
engine % RPM meter reads above 10%.
(3) to START and then release to RUN, and observe the
(f) % RPM meter (e) reads more than 60%
following:
within 30 seconds after step (2).